Products Description of Vacuum tubular furnace
The vacuum tubular furnace adopts an air-cooled structure, and the furnace body is made of high-purity alumina microcrystalline fibers adsorbed by high-temperature vacuum. Mainly used for experiments and small-scale production lines in universities, research institutes, industrial and mining enterprises, etc. It can be evacuated and filled with various protective or destructive gases, making it the best product for small-scale experiments.
Feature of Vauum Tubular Furnace
● Max temperature RT~1700℃
● High quality Mosi2 heater, Heating on two sides, good furnace temperature uniformity
● High quality performance alumina ceramic fiber insulation materials
● 30 or 50segments programmable and PID auto control
● With over temperature alarm function
● Temperature control accuracy ±1℃
|
Model |
SK2-1-12TPA2/3/4 |
SK2-2-12TPB2/3/4 |
SK2-3-12TPC2/3/4 |
SK2-6-12TPD2/3/4 |
|
Dimensions: Standard Heating zone length (mm) |
205mm/350mm/440mm |
|||
|
Dimensions: Standard Tube diameter (mm) |
∮40mm/∮60mm/∮80mm/∮100mm |
|||
|
Max.temperature |
1700℃,Continuous working temperature 1600℃. |
|||
|
Voltage(V) |
220 1P |
220 1P |
220 1P |
220 1P |
|
Thermocouple type |
K |
|||
|
Heating element |
Mosi2 heater |
|||
|
Temp.Precision |
±1℃ |
|||
|
Heating rate |
0-30℃/min free adjustment |
|||
|
Chamber material |
Using advanced high-quality alumina microcrystalline fiber material |
|||
|
Furnace structure |
Double-layer air-cooled structure, surface temperature is less than 60℃ |
|||
|
Temperature controller |
Intelligent PID temperature control instrument, 30 program segments, SSR control, PID parameter self-tuning function; program temperature rise, program heat preservation, program cooling |
|||
|
Inlet gas/Atmosphere |
It can be filled with various protective or destructive gases, Inert gases, mixed gases, nitrogen, oxygen, etc |
|||
|
Gas control |
The air inlet can be set up 1 or more air intakes, each air inlet is provided with a needle valve, connected with a vacuum gauge. The air outlet is connected with one air outlet, and all holes are equipped with needle valves. Equipped with a vacuum pump. |
|||
|
Vacuum system |
-0.1Mpa Use Stainless steel vacuum flange with vacuum gauge, valve; Easy to unload, double seal
|
|||
|
WELCOME OEM/ODM |
||||
Standard Accessories
Thermal gloves | Crucible hook | Thermocouple | Tube Block | User Manual |Tools | Vacuum pump| Quartz tube |Flange |Sealing ring |10mm gas hose |Flange support.
How to packing accessories?

We will have a list of accessories inside each package
Each package should be checked for any damage or quality issues, and then wrapped entirely with bubble wrap.
Finally, place it in the top space of the device
Optional
Different heating zone for your choose;
LCD touch screen control for choose
RS485/USB port to connect computer for choose.
High vacuum such as 10Pa,10-1Pa,10-2Pa,10-3Pa,10-4Pa.
Detail picture for 1200℃ split vacuum tube furnace
Application
Vacuum tubular furnace are widely used in scientific research and small batch production in industrial and mining enterprises, as well as in ceramics, metallurgy, electronics, glass, chemical industry, machinery, refractory materials, new material development, special materials, building materials, sintering, etc. involved in scientific research and teaching in universities and colleges. , such as sintering ,annealing, tempering, quenching and other processes.






Warm Tips
1. The air pressure in the furnace tube shall not be higher than 0.02MPa
2. Since the internal air pressure of the gas cylinder is high, the pressure reducing valve must be installed on the gas cylinder when the gas is fed into the furnace tube. To ensure safety, it is recommended to use a pressure lower than 0.02MPa
3. When the furnace body temperature is higher than 1000 ℃, the furnace tube shall not be in a vacuum state, and the pressure in the furnace tube shall be equivalent to the atmospheric pressure
4. The gas flow into the furnace tube shall be less than 200SCCM to avoid the impact of cold air flow on the hot furnace tube
5. For the sample heating experiment, it is not recommended to close the air extraction valve and air inlet valve at the flange end of the furnace tube. If it is necessary to close the gas valve to heat the sample, pay attention to the indication of the pressure gauge at all times. If the air pressure indication is greater than 0.02MPa, the exhaust valve must be opened immediately to prevent accidents (such as furnace tube rupture, flange flying out, etc.)
Warranty
One year warranty and lifelong technical support
Special tips:
1. Consumables such as heating element, quartz tube, sample crucible, etc. are not within the warranty period.
2. Damage caused by the use of corrosive gas and acid gas is not covered by the warranty.

Company profile
We are a professional manufacturer of laboratory high temperature systems since 2005. We have two factory all located in Nanyang city of comprehensive bonded zone,one is main produce equipment shell and electric parts, another for assembly and testing all equipment.
We have experienced R&D team with 10 more skilled engineers.
Our main products such as: Muffle Furnace,Tube Furnace,Atmosphere furnace,Vacuum Furnace,Bottom loading Furnace,Car bottom furnace,Degreasing sintering furnace, Vacuum brazing furnace,drying oven and Various high temperature accessories,etc.
Welcome OEM,ODM!
Certifications
CE & ISO

CE

CE

CE

ISO

Certificate name

SGS

Hot Tags: vacuum tubular furnace, China vacuum tubular furnace manufacturers, suppliers